• Users Online: 150
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 18  |  Issue : 3  |  Page : 248-256

Wettability of three denture base materials to human saliva, saliva substitute, and distilled water: A comparative in vitro study


Department of Prosthodontics and Crown and Bridge, Vydehi Institute of Dental Sciences and Research Hospital, Bengaluru, Karnataka, India

Correspondence Address:
Dr. Pavithra K Ramanna
MD – 8, Near HAL Hospital, Vimanapura, Bengaluru - 560 017, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_301_17

Rights and Permissions

Aim: The purpose of this study was to compare the wettability of saliva, a saliva substitute, and distilled water to three denture base materials. Materials and Methods: Thirty specimens of each denture base material: Heat cure polymethylmethacrylate (DPI heat cure), high-impact polymethylmethacrylate (Trevalon HI), and nylon (Valplast) were fabricated. The specimens of each denture base material were divided into three groups of ten specimens. The advancing and receding contact angles of three media: a commercially available carboxymethylcellulose-based saliva substitute (WET MOUTH), human whole saliva, and distilled water, with each denture base material were determined using a goniometer. The contact angle hysteresis was calculated as the difference between the advancing and receding contact angles. The data were statistically analyzed using univariate analysis of variance and Duncan post hoc test. Results: Low-advancing and receding contact angles were demonstrated on high-impact heat-polymerized polymethylmethacrylate denture base material. Highest hysteresis values were calculated for nylon denture base material. Conclusion: Best wettability was demonstrated on high-impact heat-polymerized polymethylmethacrylate denture base material. Based on the high hysteresis values calculated with nylon denture base material, it would possibly provide better denture retention.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2540    
    Printed60    
    Emailed0    
    PDF Downloaded331    
    Comments [Add]    

Recommend this journal