Influence of different Implant Positions and Angulations on Stress Distribution Pattern in 2-Implant Retained Mandibular Overdentures: 3D Finite Element Analysis


College Name- School of Dentistry, International Medical University, Kuala Lumpur, Malaysia

Date of Web Publication8-Jan-2021

Correspondence Address:
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-4052.306372

Rights and Permissions

How to cite this article:
Patil PG. Influence of different Implant Positions and Angulations on Stress Distribution Pattern in 2-Implant Retained Mandibular Overdentures: 3D Finite Element Analysis. J Indian Prosthodont Soc 2020;20, Suppl S1:21-2

How to cite this URL:
Patil PG. Influence of different Implant Positions and Angulations on Stress Distribution Pattern in 2-Implant Retained Mandibular Overdentures: 3D Finite Element Analysis. J Indian Prosthodont Soc [serial online] 2020 [cited 2021 Jan 16];20, Suppl S1:21-2. Available from: https://www.j-ips.org/text.asp?2020/20/5/21/306372



Background: Two implant-retained overdenture is a minimum standard of treatment for edentulous mandible. This study aims to evaluate stress-distribution in 2-implant retained mandibular overdentures with implants placed at different positions and angulations.

Methods: The 3D models of mandible (using CBCT scan DICOM-files) and denture (using 3Shape intraoral scanner DICOM-files) were developed in Materialise-Mimics-Software. A 3D model of a dental implant (3.5 mm X 12 mm) and the Locator-male-attachment (4 mm) was developed in CAD-Solidworks-software. Two implants were inserted in each 3-D model of the mandible to investigate the effect of (i) implant positions (with different distances from midline (5, 10, 15, 20 mm), and (ii) implant angulations (with different distal-angulations (5/5, 10/10, 15/15, 0/5, 0/10, 0/15 degrees) at 10 mm distance from midline in ANSYS software under vertical load of 100N unilaterally and bilaterally on first molar. Maximum Von-Mises stresses and strain-values were recorded and analyzed.

Results: Highest stresses of 4.18 MPa (under unilateral loading) and 4.2 MPa (under bilateral loading) were observed in implants at 20 mm distance. All other implant positions showed stresses less than 2.46 MPa indicating increasing trend in stresses with increase in the distance. Highest stresses of 0.93 (unilateral loading) and 0.92 MPa (bilateral loading) were observed with implants at 15/15-degree angulations. For lesser angulations, the stresses were ranging from 0.05 to 0.87 MPa on implants.

Conclusions: Implants placed more posteriorly exhibit higher stresses compared to implants placed more anteriorly. Implants placed with greater angulations displayed higher stresses than implants placed with lesser angulations.






 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article

 Article Access Statistics
    Viewed48    
    Printed0    
    Emailed0    
    PDF Downloaded3    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]