ORIGINAL ARTICLE
Year : 2021  |  Volume : 21  |  Issue : 2  |  Page : 198-203

Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique


1 Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur; Centre of Comprehensive Care, Faculty of Dentistry, Universiti Teknologi MARA, Sungai Buloh, Selangor, Malaysia
2 Department of Restorative Dentistry; Biomaterial and Technology Research Group, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
3 Department of Oral Maxillofacial Surgical and Medical Sciences, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
4 Department of Social and Preventive Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
5 Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia

Date of Submission30-Jan-2021
Date of Decision12-Mar-2021
Date of Acceptance27-Mar-2021
Date of Web Publication28-Apr-2021

Correspondence Address:
Jacob John
Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, 50603 Kuala Lumpur
Malaysia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_41_21

Rights and Permissions
  Abstract 


Aim: To investigate the effect of different cooling methods on denture base adaptation of rapid heat-cured acrylic resin using 3D superimposition technique.
Setting and Design: In vitro - Comparative study.
Materials and Methods: Denture base adaptation of two different rapid heat-cured polymethyl methacrylate acrylic resins using five different cooling methods were compared. Forty maxillary edentulous stone cast were prepared to produce the denture bases with standardized thickness. The specimens were divided into five groups (n = 8) according to type of materials and cooling methods. The master stone cast and all forty denture bases were scanned with 3Shape E1 laboratory scanner. The scanned images of each of the denture bases were superimposed over the scanned image of the master cast using Materialize 3-matic software. Three dimensional differences between the two surfaces were calculated and color surface maps were generated for visual qualitative assessment.
Statistical Analysis Used: Generalized Linear Model Test, Bonferroni Post Hoc Analysis.
Results: All bench-cooled specimens showed wide green-colored area in the overall palatal surface, while the rapid cooled specimens presented with increased red color areas especially at the palate and post dam area. Generalized Linear Model test followed by Bonferroni post hoc analysis showed significant difference in the root mean square values among the specimen groups.
Conclusion: Samples that were bench cooled, demonstrated better overall accuracy compared to the rapid cooling groups. Regardless of need for shorter denture processing time, bench cooling of rapid heat-cured PMMA is essential for acceptable denture base adaptation.

Keywords: Three-dimensional-superimposition, cooling methods, denture base adaptation, rapid cured polymethyl methacrylate


How to cite this article:
May LW, John J, Seong LG, Abidin ZZ, Ibrahim N, Danaee M, Mohd NR. Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique. J Indian Prosthodont Soc 2021;21:198-203

How to cite this URL:
May LW, John J, Seong LG, Abidin ZZ, Ibrahim N, Danaee M, Mohd NR. Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique. J Indian Prosthodont Soc [serial online] 2021 [cited 2021 May 10];21:198-203. Available from: https://www.j-ips.org/text.asp?2021/21/2/198/315064




  Introduction Top


Polymethyl methacrylate (PMMA) first introduced in 1937, was commonly used to fabricate removable prosthesis due to its favorable working characteristic, adequate mechanical strength, and comparatively low cost.[1],[2] To reduce time taken to issue or deliver a removable prosthesis, there has been continuous development on this material and its related procedures. Since the first rapid 20-min heat-cured PMMA was introduced,[3] studies have shown that there were no significant dimensional variations between conventional long heat curing cycle and rapid 20-min curing cycle.[4],[5]

Well-fitted dentures prevent hyperplasic lesion, provide chewing efficiency, and promote patient comfort. Besides the type of acrylic resin used, curing cycle and water uptake, flask cooling method also play an important role in maintaining dimensional accuracies of a removable prosthesis.[6],[7] This is because residual internal stress created during heat processing is relaxed in the stone mold with longer cooling period, thereby reducing warpage during deflasking.[6] However, conventional cooling method is time-consuming and is not practical for urgent cases or during community service in rural settings or for the frail older adults whereby shorter denture delivery time is the primary objective. It is therefore important to determine whether sufficient accuracy with good denture base adaptation can be achieved by shorter cooling period. A number of methods were introduced to study the dimensional accuracies of fixed prosthesis or denture base material such as linear measurements between two points[8],[9] and quantifying space by weight of silicone.[10] However, these methods were time-consuming and subject to operator error.[11] It is clinically more relevant to relate denture base adaptation as well as fitting of crowns by three-dimensional (3D) superimposition.[12]

To date, there has been no study using 3D superimposition technique to assess the effect of different cooling methods on denture base adaptation of rapid heat-cured acrylic. The aim of the present study was to evaluate the influence of different cooling methods on denture base adaptation of two commercially available rapid heat-cured PMMA denture base materials. The null hypothesis was that no significant differences would be recorded in denture base adaptation to the stone model of the tested materials, independently of the applied cooling procedures.


  Materials and Methods Top


Reference cast preparation and scanning

The study was approved by institutional review board. In this study, two commercially available rapid curing PMMA were used [Table 1]. The workflow of this study protocol is presented in [Figure 1]. An edentulous maxillary cast of Class 1 Type A, fulfilling the American College of Prosthodontists classification system,[13] was prepared as a reference cast. The definitive cast was duplicated using silicone-based duplication material (Wirosil, Bego USA) and 40 stone casts were prepared using Type IV dental stone (Elite Rock, Zhermack Italy). Eight casts were assigned to each study group according to the applied cooling procedure as summarized in [Table 1]. Each cast was labeled and allowed to dry for 24 h before scanning and digitizing with 3Shape E1 dental laboratory scanner (3Shape, Copenhagen, Denmark).
Figure 1: Workflow of research protocol

Click here to view
Table 1: The acrylic denture base products tested and cooling procedure used in the study

Click here to view


Preparation of denture base specimens

Wax pattern of approximately 2.0 mm thickness throughout was prepared over the reference cast. For replication of waxed denture base specimens, a silicone matrix (Exaflex Putty, GC USA) was used to standardize the thickness of all specimens.[14] Each denture base specimen was flasked by compression molding technique,[15] and heat cured in 100°C water bath for 20 min.

Denture base cooling process and three-dimensional analysis

All 40 rapid cured specimens were cooled down according to the selected groups as shown in [Table 1] and hydrated in distilled water for 24 h before scanning procedure. Intaglio surface of each denture base was scanned using the 3Shape E1 scanner. Silicone putty (Exaflex Putty, GC USA) was used to ensure an identical scanning position for each specimen.

The 3D scanned data of the denture bases were saved in a standard tessellation language (STL) format and exported to a reverse engineering software (3-matic®, Materialise, Leuven, Belgium). After virtual removal of all irrelevant scanned surfaces, STL file of every intaglio surface of the denture base was superimposed with the corresponding scanned file of the master stone cast to compare the degree surface adaptation of each specimen [Figure 2]. The entire tissue surfaces of the denture bases were superimposed with only the corresponding denture bearing area of the master cast. Superimposition was done by point-to-point matching of four anatomical landmarks, namely the buccal frenum, incisive papillae, and fovea palatine on both the surfaces. This was followed by fine tuning with automated registration, by global registration adopting closest point algorithm of the software.
Figure 2: Superimposition of denture base standard tessellation language file on master stone cast standard tessellation language file

Click here to view


Dimensional differences between the two surfaces were calculated and color surface maps were generated for visual qualitative assessment. An ideal denture would show a color map which is entirely green, giving a measurement of 0, indicating ideal adaptation of denture base to master cast. Positive deviations, from color yellow to red, show misfit with gap while negative deviations, from cyan to blue color indicates tissue compression, implicating impingement of denture base into master dental cast.

Statistical analysis

Generalized linear model test compared the accuracy of the five different specimen groups followed by Bonferroni post hoc analysis (P < 0.05). The root-mean-square (RMS) values of each superimposition were recorded for each specimen. Besides that, the mean, median, and interquartile range (IQR) of numeric distance for each superimposition were recorded. All statistical values were analyzed using the Statistical Package for Social Sciences version 22.0 (SPSS Inc., Chicago, II, USA). All scanning and superimposition procedures were performed by a single investigator. Intra-class correlation coefficient with the score of 0.85 was reported to ensure high intra-ratter reliability.


  Results Top


Color deviation map indicating the denture base adaptation of each specimen group between the master model and the intaglio surface of denture base are shown in [Figure 3]. Specimens A1, F1, and F2 showed wide green-colored area in the overall palatal surface. F3 and F4 presented with increased red color areas, especially at the palate and post dam area.
Figure 3: Color maps of intaglio surface of maxillary denture base. Nominal deviation (green); positive deviation (yellow to red) misfit with space; negative deviation (cyan to blue) tissue compression

Click here to view


[Table 2] shows the descriptive statistics of the study which includes mean, IQR, median, and RMS value of numeric superimposition distance for each specimen groups. With regard to accuracy of denture base adaptations, lowest RMS mean value was recorded in F1 group and highest RMS mean value was found in F3 group. Significant difference was reported in the RMS values among the specimen groups (P = 0.002) according to the Generalized Linear Model test. Overall accuracy of F1 was comparable to ISO certified A1 when cooled down according to the manufacturer's instructions as the difference was not statistically significant. Based on Bonferroni post hoc analysis, F3 was significantly different from F1 and F2, while F4 was significantly different from F1.
Table 2: Measured surface deviations between scanned master casts and maxillary denture bases

Click here to view



  Discussion Top


An affordable, stronger, and shorter duration for denture processing is crucial to reduce denture delivery time for targeted special needs population who suffer from physical ailment, chronic diseases, or other social and economic challenges.[16],[17] Simultaneously, good denture base adaptation with limited deformation and shrinkage is vital to every aspect of the wearer's experience.[18],[19],[20]

Many methods have been used to study the dimensional accuracies of denture base materials, ranging from measuring between two reference points on denture base with optical comparator, measuring microscope,[20] post dam discrepancies,[21] vertical dimension or incisor pin movement,[22],[23] quantifying space between denture and master cast with the weight of silicone material[10],[19],[24] and lately by superimposing scanned data using specified software.[12],[25],[26],[27]

Although manual measuring methods are easy to use, inexpensive and readily accessible, they are time-consuming and subject to operator error.[11],[28] Furthermore, these methods only measure linear changes between two points, whereas dimensional changes occurred three dimensionally during processing. Therefore, it is more clinically relevant to relate the denture adaptation by superimposing STL files using engineering software.[27],[29]

Based on the results of this study, the null hypothesis was rejected because significant differences were observed between the five groups (P < 0.05). Comparison between the 3D scanned image of the denture base and stone model of the upper complete edentulous arch revealed that the adaptability of the bench cooled (A1, F1, and F2 groups) denture bases were significantly better than those that were rapidly cooled (F3 and F4) (P < 0.001). These findings are consistent with a number of studies[6],[19],[30] which show better adaptation when bench cooled as compared to rapid cooling. The cooling rate of heat-cured acrylic resins has long been accepted as a means of controlling their crystallinity and shrinkage.[31] This is due to the reaction taking place during heat polymerization,[32] whereby there is a difference in the thermal contraction between stone mold and acrylic resin, leading to the production of internal stress within the processed denture. When this residual stress is released on deflasking, higher shrinkage was observed in rapidly cooled PMMA compared to slow or bench cooled acrylic, since more elastic strain was released during removal from the stone mold.[30],[33]

On the color-coded map, ideal adaptation was shown as homogeneous green area as seen in A1, F1 and F2 bench cooling groups. Positive deviation, displayed as yellow to red, was more pronounced in the F3 and F4 rapid cooling groups, indicating the presence of space between the denture base and the cast. This space or gap, especially at the posterior palatal seal area, indicates there was warpage of denture upon deflasking in rapid cooling groups which also coincides with the finding of significantly higher RMS value reported in these groups. It has long been recognized that the least deformation of the prosthesis is achieved when gradual post processing cooling is undertaken. When rapid cooling rates are used, the polymer chains are highly constrained, with reduced segmental mobility and the resultant residual stresses are high, affecting the dimensional stability and fitting of the prosthesis.[33] In addition, poor outcome is also likely due to sudden temperature reduction or quenching[34],[35] which creates differential shrinkage vectors and contraction at various denture areas.

In terms of analyzing the digital data, unlike most of the earlier studies[12],[36] which only analyzed the median of numeric distance to determine the accuracy of each specimen group, in this study, RMS value was considered to determine the accuracy of each specimen group. According to Pearson's correlation coefficient, there was no correlation between RMS value and median of numeric distance analyzed. Hence, RMS value remains the chosen parameter to evaluate accuracy of each superimposition.

This in vitro study has some limitations. The denture base adaptation was compared against a standard edentulous master cast. The master cast does not replicate the dynamic characteristic of oral mucosa during function, including saliva and a limited mouth opening space. Moreover, unlike fixed prosthesis,[37] adaptation of removable prosthesis is highly influenced by compressibility of mucosa during mastication.[38] In addition, the software first performed point-based registration using fixed anatomical landmark followed by overall matching using closest corresponding points between two surfaces. Due to the complicated algorithm in the process of automated superimposition, true individual displacement may not be replicated accurately. Nevertheless, to date, this remains the most updated protocol for studies of similar nature. In order to negate this limitation, haptic technology should be incorporated into the alignment software to relate it to actual tactile sensation occurring during denture base adaptation.[14] More studies that consider the true clinical environment should be undertaken to assess patient-related outcome measures.


  Conclusion Top


Within the limitations of this in vitro study, the 3D superimposition technique established that the samples that were bench cooled, demonstrated better overall accuracy as compared to the rapid cooling groups. Hence, in situations when time is of essence, bench cooling rapid heat-cured PMMA produces acceptable denture base adaptation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Chander NG. Polymethyl metha acrylate denture base: An overview. J Indian Prosthodont Soc 2018;18:87.  Back to cited text no. 1
[PUBMED]  [Full text]  
2.
Ali AA, John J, Mani SA, El‐Seedi HR. Effect of thermal cycling on flexural properties of microcrystalline cellulose-reinforced denture base acrylic resins. J Prosthodont 2019;29:611-6.  Back to cited text no. 2
    
3.
Firtell DN, Green AJ, Elahi JM. Posterior peripheral seal distortion related to processing temperature. J Prosthet Dent 1981;45:598-601.  Back to cited text no. 3
    
4.
de Negreiros WA, Consani RL, Verde MA, da Silva AM, Pinto LP. The role of polymerization cycle and post-pressing time on tooth movement in complete dentures. Braz Oral Res 2009;23:467-72.  Back to cited text no. 4
    
5.
Polychronakis N, Yannikakis S, Zissis A. A clinical 5-year longitudinal study on the dimensional changes of complete maxillary dentures. Int J Prosthodont 2003;16:78-81.  Back to cited text no. 5
    
6.
Kimoto S, Kobayashi N, Kobayashi K, Kawara M. Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material. J Dent 2005;33:57-63.  Back to cited text no. 6
    
7.
Consani RL, Domitti SS, Mesquita MF, Consani S. Influence of flask closure and flask cooling methods on tooth movement in maxillary dentures. J Prosthodont 2006;15:229-34.  Back to cited text no. 7
    
8.
Keenan PL, Radford DR, Clark RK. Dimensional change in complete dentures fabricated by injection molding and microwave processing. J Prosthet Dent 2003;89:37-44.  Back to cited text no. 8
    
9.
Habib SR, Al Otaibi AK, Al Anazi TA, Al Anazi SM. Comparison between five CAD/CAM systems for fit of zirconia copings. Quintessence Int 2018;49:437-444.  Back to cited text no. 9
    
10.
McLaughlin JB, Ramos V Jr., Dickinson DP. Comparison of fit of dentures fabricated by traditional techniques versus CAD/CAM technology. J Prosthodont 2019;28:428-35.  Back to cited text no. 10
    
11.
Brosky ME, Pesun IJ, Lowder PD, DeLong R, Hodges JS. Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy. J Prosthet Dent 2002;87:204-9.  Back to cited text no. 11
    
12.
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56.  Back to cited text no. 12
    
13.
McGarry TJ, Nimmo A, Skiba JF, Ahlstrom RH, Smith CR, Koumjian JH. Classification system for complete edentulism. J Prosthodont 1999;8:27-39.  Back to cited text no. 13
    
14.
Norvell NG, Korioth TV, Cagna DR, Versluis A. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks. J Prosthet Dent 2018;120:123-31.  Back to cited text no. 14
    
15.
Skinner EW, Jones PM. Dimensional stability of self-curing denture base acrylic resin. J Am Dent Assoc 1955;51:426-31.  Back to cited text no. 15
    
16.
Ceruti P, Mobilio N, Bellia E, Borracchini A, Catapano S, Gassino G. Simplified edentulous treatment: A multicenter randomized controlled trial to evaluate the timing and clinical outcomes of the technique. J Prosthet Dent 2017;118:462-7.  Back to cited text no. 16
    
17.
John J, Ann Mani S, Palaniswamy K, Ramanathan A, Razak AA. Flexural properties of poly (methyl methacrylate) resin reinforced with oil palm empty fruit bunch fibers: A preliminary finding. J Prosthodont 2015;24:233-8.  Back to cited text no. 17
    
18.
Allen PF, McMillan AS. A longitudinal study of quality of life outcomes in older adults requesting implant prostheses and complete removable dentures. Clin Oral Implants Res 2003;14:173-9.  Back to cited text no. 18
    
19.
Jadhav SS, Mahajan N, Sethuraman R. Comparative evaluation of the amount of the residual monomer in conventional and deep-frozen heat cure polymethylmethacrylate acrylic resin: An in vitro study. J Indian Prosthodont Soc 2018;18:147-53.  Back to cited text no. 19
    
20.
Sakaguchi RL, Ferrancane J, Powers JM. Craig's Restorative Dental Materials. 14th ed. St Louis: Elsevier; 2012.  Back to cited text no. 20
    
21.
Lee CJ, Bok SB, Bae JY, Lee HH. Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods. Dent Mater J 2010;29:411-7.  Back to cited text no. 21
    
22.
Basso MF, Giampaolo ET, Machado AL, Pavarina AC, Vergani CE. Evaluation of the occlusion vertical dimension of complete dentures after microwave disinfection. Gerodontology 2012;29:e815-21.  Back to cited text no. 22
    
23.
Campos MS, Cavalcanti BN, Cunha VP. Occlusal changes in complete dentures processed by pack-and-press and injection-pressing techniques. Eur J Prosthodont Restor Dent 2005;13:78-80.  Back to cited text no. 23
    
24.
Hsu CY, Yang TC, Wang TM, Lin LD. Effects of fabrication techniques on denture base adaptation: An in vitro study. J Prosthet Dent 2020;124:740-7.  Back to cited text no. 24
    
25.
Cole D, Bencharit S, Carrico CK, Arias A, Tüfekçi E. Evaluation of fit for 3D-printed retainers compared with thermoform retainers. Am J Orthod Dentofacial Orthop 2019;155:592-9.  Back to cited text no. 25
    
26.
Hwang HJ, Lee SJ, Park EJ, Yoon HI. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing. J Prosthet Dent 2019;121:110-7.  Back to cited text no. 26
    
27.
Manjin Z, Mariko H, Yuka S, Kelimu ME, Rongguang L, Yuan G, et al. OSC10: Observation of the teeth position in cleft lip and palate patients using three-dimensional assessment. J Indian Prosthodont Soc. 2018;18 (Suppl 1):S11.  Back to cited text no. 27
    
28.
Dastane A, Vaidyanathan TK, Vaidyanathan J, Mehra R, Hesby R. Development and evaluation of a new 3‐D digitization and computer graphic system to study the anatomic tissue and restoration surfaces. J Oral Rehab 1996;23:25-34.  Back to cited text no. 28
    
29.
Artopoulos A, Juszczyk AS, Rodriguez JM, Clark RK, Radford DR. Three-dimensional processing deformation of three denture base materials. J Prosthet Dent 2013;110:481-7.  Back to cited text no. 29
    
30.
Fenlon MR, Juszczyk AS, Rodriguez JM, Curtis RV. Dimensional stability of complete denture permanent acrylic resin denture bases; a comparison of dimensions before and after a second curing cycle. Eur J Prosthodont Restor Dent 2010;18:33-8.  Back to cited text no. 30
    
31.
Laot CM, Marand E, Schmittmann B, Zia R. Effects of cooling rate and physical aging on the gas transport properties in polycarbonate. Macromolecules 2003;36:8673-84.  Back to cited text no. 31
    
32.
Ohyama A, Imai Y. Differential scanning calorimetric study of acrylic resin powders used in dentistry. Dent Mater J 2000;19:346-51.  Back to cited text no. 32
    
33.
Komiyama O, Kawara M. Stress relaxation of heat-activated acrylic denture base resin in the mold after processing. J Prosthet Dent 1998;79:175-81.  Back to cited text no. 33
    
34.
Savirmath A, Mishra V. A comparative evaluation of the linear dimensional changes of two different commercially available heat cure acrylic resins during three different cooling regimens. J Clin Diagnostic Res 2016;10:ZC50-4.  Back to cited text no. 34
    
35.
Kobayashi N, Komiyama O, Kimoto S, Kawara M. Reduction of shrinkage on heat‐activated acrylic denture base resin obtaining gradual cooling after processing. J Oral Rehabil 2004;31:710-6.  Back to cited text no. 35
    
36.
Wimmer T, Eichberger M, Lümkemann N, Stawarczyk B. Accuracy of digitally fabricated trial dentures. J Prosthet Dent 2018;119:942-7.  Back to cited text no. 36
    
37.
Jang Y, Sim JY, Park JK, Kim WC, Kim HY, Kim JH. Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts. J Prosthet Dent 2019;123:135-42.  Back to cited text no. 37
    
38.
Mubarak S, Hmud A, Chandrasekharan S, Ali AA. Prevalence of denture-related oral lesions among patients attending College of Dentistry, University of Dammam: A clinico-pathological study. J Int Soc Prev Community Dent 2015;5:506-12.  Back to cited text no. 38
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed80    
    Printed0    
    Emailed0    
    PDF Downloaded10    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]