• Users Online: 760
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 21  |  Issue : 4  |  Page : 397-404

Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study


Department of Prosthodontics, Crown and Bridge Including Implantology, M R Ambedkar Dental College and Hospital, Bengaluru, Karnataka, India

Correspondence Address:
Syeda Ayesha
Department of Prosthodontics, Crown and Bridge Including Implantology, M R Ambedkar Dental College and Hospital, 1/36 Cline Road, Balaji Layout, Cooke Town, Bengaluru - 560 005, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_239_21

Rights and Permissions

Aim: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. Settings and Design: In Vivo Comparative study. Materials and Methods: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. Statistical Analysis Used: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. Results: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). Conclusion: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed266    
    Printed0    
    Emailed0    
    PDF Downloaded61    
    Comments [Add]    

Recommend this journal