Year : 2022  |  Volume : 22  |  Issue : 3  |  Page : 240-248

Evaluation and comparison of vertical marginal fit of three different types of multiunit screw-retained framework fabricated for an implant-supported prosthesis – An in vitro study


1 Department of Prosthodontics, Faculty of Dental Sciences, SGT University, Gurgaon, Haryana, India
2 Department of Oral Pathology, Faculty of Dental Sciences, SGT University, Gurgaon, Haryana, India

Correspondence Address:
Bhupender Kumar Yadav
House No. 1358, Sector 10 A, Gurgaon - 122 001, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_28_22

Rights and Permissions

Aim: The present study aimed to evaluate on a comparative basis the vertical marginal fit between conventionally casted, direct metal laser sintered (DMLS), and milled computer-aided design/computer-aided manufacturing (CAD-CAM) one-piece metal framework supported by five implants using one-screw test and screw resistance test. Settings and Design: This is an in vitro study. Materials and Methods: Five implants were placed parallel to one other in a Styrofoam master model. A total of 30 implant-supported screw-retained superstructures were manufactured using three techniques, i.e., conventionally casted, milled, and sintered. To evaluate the vertical marginal discrepancy, screw resistance test, and one-screw test were used, and measurements were made using a stereomicroscope. Statistical Analysis Used: The data was analysed using two statistical tests, i.e., ANOVA and the post hoc Bonferroni test. Results: On evaluating the frameworks using one-screw test, the mean vertical misfit value at the terminal implant for the control group was 292.58 ± 15.46μm, for conventionally casted framework 398.41 ± 21.13 μm, for DMLS 343.44 ± 24.73 μm, and for CAD-CAM was 304.03 ± 14.23 μm, whereas the average misfit values at four implants on applying screw resistance test were 1268.65 ± 84.24 (control), 1774.88 ± 67.70 (casted), 1508.02 ± 62.19 (DMLS), and 1367.29 ± 81.87 (CAD-CAM). The average misfit values on two implants using screw resistance test were 635.02 ± 57.33 for the control group; for conventionally casted, it was 879.75 ± 35.93; for (DMLS) framework, it was 761.51 ± 32.85; and for milled CAD-CAM framework, it was 687.07 ± 42.17 μm. Conclusion: The mean vertical marginal discrepancy, when compared with control, was least in milled CAD-CAM frameworks, followed by sintered DMLS and conventionally casted frameworks. Hence, according to the present study, CAD/CAM technique is recommended to achieve maximum marginal fit in full mouth screw-retained implant-supported FDPs.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed282    
    Printed14    
    Emailed0    
    PDF Downloaded56    
    Comments [Add]    

Recommend this journal