RESEARCH
Year : 2023  |  Volume : 23  |  Issue : 1  |  Page : 38-44

In vitro comparison of the color degradation of two computer-aided design/computer-aided manufacturing provisional materials: A 12-month simulation


1 Department of Prosthodontics, Saint Joseph University of Beirut, Beirut, Lebanon
2 Department of Pediatrics, McGill University, Saint Joseph University of Beirut, Beirut, Lebanon

Correspondence Address:
Suzanna Maria Sayegh
Saint Joseph University, Beirut
Lebanon
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jips.jips_119_22

Rights and Permissions

Aim: This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months. Setting and Design: The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon. Materials and Methods: The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp® and Ceramill® TEMP were measured using the VITA Linearguide 3D MASTER® and a conversion table to extract the CIE L*a*b* values on a white background (n = 30). Statistical Analysis Used: The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests. Results: The mean ΔET1/T0, ΔET2/T0, and ΔET3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp® and the Ceramill® TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill® TEMP group compared to the VITA CAD Temp® group. Conclusions: The Ceramill® TEMP changed color more and faster than the VITA CAD Temp®. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed410    
    Printed10    
    Emailed0    
    PDF Downloaded86    
    Comments [Add]    

Recommend this journal